Revision History for Chapter 2 – Cleaning Procedures

Rev. No.

Date

Authors

Description of Revision

2.1 – General Cleaning Procedures

00

 

 

 

01

11/05

 

 

 

11/07

M. Kushner

 

 

 

M. Kushner

1)   Edited/updated to specify the exact sink where labware should be cleaned.

2)   Replaced references to rinse tanks with QDR (Quick Dump Rinse) and SRD (Spin-Rinse/Dryer).

3)       Replaced Tystar for Tylan throughout the chapter, and included the new standby recipes names for each furnace.

1)       Noted nitrite gloves rather than the old latex gloves.

2)      Corrected the order of chemical makeup of RCA1 and RCA2 cleans.

3)      Corrected the hydrogen peroxide chemical formulae.

2.2 – Tystar & Lam Monitor Wafer Preparation & Rework

00

01

1/05

7/08

J. Chang

J. Chang

N/A

Minor revisions.

2.3 – Sink3 Operation

00

01

 

02

11/02

10/05

 

9/08

K. Chan, M. Kushner

W. Flounders

 

K. Chan

N/A

-  Suppression of labwide vacuum drain system to be replaced by new definition of Full Plenum Lockout Alarm.

-  Added N2 flowmeter procedure and made minor changes.

2.4 – Sink4 Operation

00

01

02

 

03

2/01

10/03

10/05

 

8/08

M. Kushner

M. Kushner

W. Flounders

 

K. Chan

N/A

N/A

-  Suppression of labwide vacuum drain system to be replaced by new definition for Full Plenum Lockout Alarm.

-  Revised the chapter manual to match the description of sink4 in a better way.

2.5 – Sink5 (Y2)

00

01

02

03

 

04

 

05

5/02

9/02

8/04

10/5

 

10/5

 

8/08

K. Chan, M. Kushner

K. Chan, M. Kushner

K. Chan, M. Kushner

M. Kushner, W. Flounders

 

M. Kushner

 

M. Kushner

N/A

N/A

N/A

-  Addition of Section 6.9 on fire suppression system and new definition of Full Plenum Lockout Alarm.

1)       Corrected the flash point temperature of PRS-3000 to 90ēC.

2)       Eliminated reference to HMDS bubbler at this sink in Section 9.5.1.5.

1)   Added references to the pre-furnace clean metal bath in Sections 3.0, 6.0, 8.0 and 9.1.

2)   Deleted any remaining references to the obsolete HMDS setup at this sink.

3)   Revamped Section 9.5 to describe the gravity drain spigot system for the PRS-3000 photoresist stripper.

4)    Deleted Figure 4 (HMDS timer).

2.6 – Sink6 (MOS Clean)

00

01

02

03

7/03

6/04

8/04

10/5

M. Kushner, K. Chan

S. Parsa

M. Kushner

W. Flounders

N/A

N/A

N/A

-  Suppression of labwide vacuum drain system to be replaced by new definition of Full Plenum Lockout Alarm.

2.7 – Sink7 (VLSI)

00

01

02

03

04

 

05

5/02

9/02

6/04

8/04

10/05

 

8/07

K. Chan, M. Kushner

K. Chan, M. Kushner

S. Parsa

M. Kushner

W. Flounders

 

W. Flounders

N/A

N/A

N/A

N/A

-  Suppression of labwide vacuum drain system to be replaced by new definition of Full Plenum Lockout Alarm.

-  Added Wet Etching of Silicon Nitride with Heated Phosphoric Acid info (pdf file)

2.8 – Sink8 (Non-MOS Clean)

00

01

02

03

04

2/01

9/02

10/03

8/04

10/05

M. Kushner, K. Chan

M. Kushner, K. Chan

K. Chan

M. Kushner

W. Flounders

N/A

N/A

N/A

N/A

-  Suppression of labwide vacuum drain system to be replaced by new definition of Full Plenum Lockout Alarm.

2.9 – Sink9 & Spin Dryer Operation

00

01

02

03

 

04

9/02

6/04

8/04

10/05

 

9/08

M. Kushner

S. Parsa

M. Kusner

W. Flounders

 

S. Parsa

N/A

N/A

N/A

-  Suppression of labwide vacuum drain system to be replaced by new definition of Full Plenum Lockout Alarm.

-  Changed the purpose and application of the sink; minor modifications.

2.10 – Old Lab Sinks Operation (432C sink & black utility sink)

00

01

02

7/04

11/06

6/07

M. Kushner

W. Flounders

M. Kushner

N/A

-  Modified Section 8.0.

-  Modified Sections 8.1, 8.2 and 9.1.

2.11 – Sink 432A (Old Lab)

00

01

9/02

10/05

M. Kusner

R. Hamilton

N/A

-  Deletion of paragraph 6.7 in 6.0 Safety about fire supression system.

2.12 – Sinkplate - Electroplating

00

01

02

03

4/01

7/03

12/04

6/07

J. Chang

D. Meir

S. Parsa, P. Guillory

D. Queen

N/A

N/A

N/A

-  Removed references to gooseneck and ICW supplies as they are no longer available at the sink.

-  Updated the location of the HF chemical cabinet.

2.13 – Tousimis 815 Critical-Point Dryer (small samples)

00

01

02

03

04

05

6/01

9/03

9/04

9/05

7/07

7/07

M. Young

R. Su

R. Hamilton, W. Flounders

M. Linan

W. Flounders

T. Fujii

N/A

N/A

N/A

-  Addition of Section 3.3 in Scope

-  Added same paragraphs in 10.0 Troubleshooting Guidelines, than in Chapter 2.14 (cpd)

-  Reviewed – No changes necessary.

2.14 – Tousimis 915B Critical-Point Dryer

00

01

02

03

04

05

06

5/00

6/01

7/03

9/04

5/05

7/07

8/07

J. Chang

M. Young, M. Helmbrecht

W. Flounders

W. Flounders, R. Hamilton

M. Linan

W. Flounders

M. Tien

N/A

N/A

N/A

N/A

N/A

-  Added subsection 10.2 in Section 10.0 Troubleshooting Guidelines (same paragraphs as in 2.13)

-  Added sentence in 9.2.7, Subsection 10.3, and corrected few typos.

9/08 – ML